Clearone Interact Serial Command Guide Instrukcja Użytkownika Strona 21

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 61
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 20
Page 16 of 56
CLOCK Clock Set
This command sets or reports the current time.
ARGUMENT DETAILS
Name Type Size Values
Date Unsigned Integer 1 1 31
Month Unsigned Integer 1 1 12
Year Unsigned Integer 2
2000 2099
(NULL to Query in Text)
Hours Unsigned Integer 1 00 23
Minutes Unsigned Integer 1 00 59
Seconds Unsigned Integer 1 00 59
Day of Week Unsigned Integer 1
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
TEXT FORM DETAILS
COMMAND FORM: DEVICE CLOCK [Date Month Year Hours Minutes Seconds Day]
COMPRESS Compressor
This command selects/reports the compressor configuration.
ARGUMENT DETAILS
Name Type Size Values
Channel Channel 1 See GroupAndChannels
Group Group 1 5 (P)
Threshold Signed Integer 1
-60 20 dB
(Null to query in text)
Ratio
Unsigned
Integer
1 1 20
Attack Unsigned Float 2 0.00 100.00 ms
Release
Unsigned
Integer
2 100 2000 ms
Gain Unsigned Float 4 0.00 20.00 dB
TEXT FORM DETAILS
COMMAND FORM:DEVICE COMPRESS <Channel> [Threshold Ratio Attack Release Gain]
Przeglądanie stron 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 60 61

Komentarze do niniejszej Instrukcji

Brak uwag